FLIR A35
FLIR A35

Ürün Hakkında

Specifications
Digital I/O connector type
12-pole M12 connector (shared with Digital Synchronization and External power)
Digital Inputs
General Purpose, 1× opto-isolated, "0"
Digital Output Purpose
General purpose output to ext. device (programmatically set)
Digital Outputs
1× opto-isolated, 2–40 VDC, max 185 mA
EMC
•EN 61000-6-2 (Immunity) •EN 61000-6-3 (Emission) •FCC 47 CFR Part 15 Class B (Emission)
f-number
1.1
Image Frequency
60 Hz
Thermal Sensitivity/NETD
<0.05°C @ 30°C (86°F) / 50 mK
Accuracy
±5°C (±9°F) or ±5% of reading
Communication & Data Storage
Digital I/O connector type
12-pole M12 connector (shared with Digital Synchronization and External power)
Digital I/O isolation voltage
500 VRMS
Digital I/O supply voltage
2–40 VDC, max 200 mA
Digital Inputs
General Purpose, 1× opto-isolated, "0"
Digital Output Purpose
General purpose output to ext. device (programmatically set)
Digital Outputs
1× opto-isolated, 2–40 VDC, max 185 mA
Digital Synchronization Connector Type
12-pole M12 connector (shared with Digital I/O and External power)
Ethernet
Control and image
Ethernet Communication
GigE Vision ver. 1.2 Client API GenICam compliant
Ethernet Connector Type
RJ-45
Ethernet Image Streaming
8-bit monochrome @ 60 Hz Signal linear/ DDE Automatic/ Manual Flip H&V 14-bit 320 × 256 pixels @ 60 Hz Signal linear/ DDE Temperature linear GigE Vision and GenICam compatible
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 0 Power
Ethernet Protocols
TCP, UDP, ICMP, IGMP, DHCP, GigEVision
Ethernet Standard
IEEE 802.3
Ethernet Type
Gigabit Ethernet
Synchronization in
1×, non-isolated
Synchronization in - purpose
Frame sync in to control camera
Synchronization in - type
LVC Buffer @3.3V, "0" 2.0 V.
Synchronization out
1×, non-isolated
Synchronization out - purpose
Frame sync out to control another Ax5 camera
Synchronization Out - type
LVC Buffer @ 3.3V, "0"=24 MA max, "1"= –24 mA max.
Imaging & Optical
Detector Pitch
17 µm
Detector Time Constant
Typical 12 ms
Detector Type
Focal plane array (FPA), uncooled VOX microbolometer
Field of view (FOV)
13° × 10°
FLIR Screen-EST Mode
No
f-number
1.1
Focal Length
25 mm (0.98 in.)
Focus
Fixed
Image Frequency
60 Hz
IR Resolution
320 × 256 pixels
Spatial resolution (IFOV)
0.680 mrad
Spectral Range
7.5–13 µm
Thermal Sensitivity/NETD
<0.05°C @ 30°C (86°F) / 50 mK
Measurement & Analysis
Accuracy
±5°C (±9°F) or ±5% of reading
Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Camera size (L x W x H)
107.8 × 49.6 × 46.6 mm (4.2 × 1.9 × 1.8 in.)
Emissivity Correction
Variable from 0.5 to 1.0
Measurement Corrections
Global object parameters
Object Temperature Range
-25°C to 100°C (-13 to 212°F) / –40°C to 550°C (-40 to 1022°F)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
General
Base Mounting
4 × M3 thread mounting holes (bottom)
Housing material
Magnesium and aluminum
Package Includes
Hard transport case Infrared camera with lens Base support Cable tie (2 ea.) Ethernet cable CAT-6, 2m/6.6 ft (2 ea.) FLIR ResearchIR Standard 4 Focus adjustment tool Gooseneck Mains cable kit (UK,EU,US) PoE Injector (power over Ethernet) Printed documentation Table stand
Packaging Size
370 x 180 x 320 mm (14.6 x 7.1 x 12.6 in.)
Environmental & Certifications
EMC
•EN 61000-6-2 (Immunity) •EN 61000-6-3 (Emission) •FCC 47 CFR Part 15 Class B (Emission)
Encapsulation
IP 40 (IEC 60529) with base support mounted
Humidity (Operating and Storage)
IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F)
Operating Temperature Range
–15°C to +50°C (+5°F to +122°F) The operating temperature range assumes that the camera is mounted on the base support (included in the package) or a similar type of heatsink.
Shock
25 g (IEC 60068-2-27)
Storage Temperature Range
–40°C to 70°C (–40°F to 158°F)
Tripod Mounting
UNC ¼"-20 (on three sides)
Vibration
2 g (IEC 60068-2-6 & MIL-STD810G)
Power
External Power Connector Type
12-pole M12 connector (shared with Digital I/O and Digital Synchronization )
External Power Operation
12/24 VDC, < 3.5 W nominal < 6.0 W absolute max
Voltage
Allowed range 10–30 VDC

  • 320 × 256

Sizler için Seçtiklerimiz

FLIR i65
  • El Tipi Termal Kameralar

FLIR i65

Android Tabanlı Yeni Nesil Termal Görüntüleme Kamerası

FLIR i35
  • El Tipi Termal Kameralar

FLIR i35

Android Tabanlı Yeni Nesil Termal Görüntüleme Kamerası

FLIR C8
  • El Tipi Termal Kameralar

FLIR C8

Kompakt Termal Kamera

FLIR C5
  • El Tipi Termal Kameralar

FLIR C5

Bulut bağlantısı ve Wi-Fi ile hızla inceleyin, belgeleyin ve paylaşın

FLIR E5 Pro
  • El Tipi Termal Kameralar

FLIR E5 Pro

Ignite™ Cloud Özellikli Pro Serisi Kızılötesi Kamera

FLIR E6 Pro
  • El Tipi Termal Kameralar

FLIR E6 Pro

Ignite™ Cloud Özellikli Pro Serisi Kızılötesi Kamera

FLIR E8 Pro
  • El Tipi Termal Kameralar

FLIR E8 Pro

Ignite™ Cloud Özellikli Pro Serisi Kızılötesi Kamera

FLIR E96
  • El Tipi Termal Kameralar

FLIR E96

Gelişmiş Termal Görüntüleme Kamerası

FLIR Si2-Pro
  • Akustik Kameralar

FLIR Si2-Pro

Kısmi Deşarj Tespiti, Basınçlı Sızıntı Tespiti ve Mekanik Arıza Tespiti için Endüstriyel Akustik Görüntüleme Kamerası

Online kataloğumuzu inceleyin

Yardıma ihtiyacınız varsa bizimle iletişime geçebilirsiniz.